Del ozone Spa-Eclipse Installationshandbuch Seite 11

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 10
Eclipse Installation & Operations Manual
9
4C-2. Ozone Module Replacement
The EC-10, EC-20, and EC-40 have 2, 4, and 6 Ozone Modules,
respectively. When the green indicator lights go out, the
corresponding Ozone Module will need to be replaced.
To replace an Ozone Module:
1. Disconnect the Ozone Module from the Manifold and pull the
Ozone Module from the Bracket so it hangs by its wires.
2. Locate the Power Supply Connector and disconnect it from the
wire harness.
3. Remove the Power Supply Mounting Screw; make sure to
note plastic spacer and the star washer positions for proper
reassembly. The Ozone Module and Power Supply can now be
removed from the unit.
4. Install the new Ozone Module by reversing the above steps.
4D. Trouble Shooting
Knowledge of electrical applications is required for trouble shooting.
Contact a certified electrician if you are unsure of your ability to
service the equipment. Improper servicing will void generator
warranty. If any condition persists contact DEL technical support
(see section 4E)
4D-1 Symptom: Module Indicator Lights not lit when pool system is
on.
1. No power to the ozone generator from the power source:
a. Check circuit breaker at the power distribution box.
b. Check for loose connections or wiring breaks from the power
distribution box to the generator.
c. The fuse in the unit has blown and needs to be replaced. The
fuse is a replaceable glass, .25” x 1.25”, 1 amp, slo-blo type.
2. G.F.C.I. has tripped.
a. Check power cord and reset G.F.C.I.
4D-2 Symptom: Flowmeter not indicating flow.
1. Injector not supplying adequate suction.
a. Check pump, filters, and skimmers to ensure water is flowing
through injector.
b. Ensure that there is no debris clogged inside the injector.
2. Tubing is impaired.
a. Check for kinks or clogs.
b. Check for cracks or cuts.
c. Check connections.
d. Check that the check valve is installed with the arrow pointing
towards the injector.
Seitenansicht 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16

Kommentare zu diesen Handbüchern

Keine Kommentare